4.4 KiB
Calibration guide
The virtual Kinect needs a one-time calibration so the player-space scale, the depth placement,
and the mirror orientation match your room and camera mount. The logic lives in
core/calibration/ (calibration.h / calibration.cpp), which computes, persists, and
reload-tests a CalibrationConfig.
Current limitation: not yet wired into runtime.
core/calibration/produces and reloads a config file, and that round-trip is unit-tested, but no runtime surface reads it back yet. Today the tracker places depth using a hard-coded default origin,DEFAULT_Z0_METERS = 2.5(tracker/joint_mapping.py), regardless of what you calibrate. Running the steps below exercises and validates the calibration math and writes a real config file, but it does not yet change what the running tracker, OpenNI2 driver, USB emitter, or Windows shim do at runtime. Wiring the saved config into those startup paths is a known pending step.
Calibration is two short poses: a mirror-confirm (raise one arm) and a T-pose (arms out). Both are read from the live tracker's pose output; no extra tool is needed beyond the running tracker.
Why calibrate
- Scale. A single webcam has no absolute size. The T-pose shoulder span fixes the player-space
scale so your body maps to roughly Kinect-sized skeleton coordinates. The target shoulder width
is 0.40 m (
kTargetShoulderWidthMeters). - Depth placement (Z0). Your standing distance from the camera becomes the depth origin, so the synthetic depth sits in the Kinect's valid band instead of pegging at a floor value. Z0 is clamped to the Kinect's usable range, 0.8 m to 4.0 m.
- Mirror. A raw camera image is left/right flipped relative to how a Kinect presents the scene. The mirror flag makes your anatomical right arm land where the host tracker and the game expect it. Getting this wrong is the most common "my moves are inverted" bug (see troubleshooting).
Step 1: mirror confirm (raise your right arm)
Stand facing the camera and raise only your anatomical right arm, left arm down.
confirm_mirror_raise_right_arm() checks that exactly the right arm is up (right wrist above the
right shoulder, left wrist at or below its shoulder). It then sets the global mirror flag from
where that raised arm appears horizontally in the image: if the raised arm shows up on image-left,
the feed is mirrored and the flag is set so downstream consumers flip it back.
If the check fails it returns an error ("mirror confirmation requires only the right arm raised"); lower your left arm fully and raise only the right, then retry.
Step 2: T-pose (arms straight out)
Stand at your normal playing distance and hold a T-pose: both arms straight out to the sides, level with your shoulders, facing the camera, whole body in frame.
calibrate_tpose() reads one TposeObservation:
person_detectedmust be true (one clean detection),root_depth_metersbecomes the clamped Z0 depth origin,normalized_shoulder_widthsetsplayer_scaleso your shoulders map to 0.40 m,floor_planecarries the floor estimate through unchanged,mirrorcomes from step 1.
It produces a CalibrationConfig (mapping intrinsics, smoothing parameters, player scale, floor
plane). Invalid or non-finite inputs (no person, zero shoulder width) fail with a clear error
rather than writing a bad config.
Step 3: save and reuse
save_config() writes the calibration to a plain-text key/value file; load_config() reads it
back, and this save/reload round-trip is covered by tests. No runtime surface loads this file
yet - the tracker, the OpenNI2 SynthKinect driver, the USB emitter (core/protocol), and the
Kinect10.dll shim do not call load_config() on startup today; the tracker instead uses the
hard-coded DEFAULT_Z0_METERS = 2.5 for every session. Once that wiring lands, all of those
surfaces are expected to consume the same saved file so you calibrate once and every path agrees.
Recalibrate when you move the camera, change your playing distance, or switch rooms (once wired into runtime, below). The mirror step is worth repeating any time left/right feels wrong in a game.
Tips
- Calibrate in the lighting you will play in; poor light degrades the pose estimate the calibration is built from.
- Keep your whole body in frame for the T-pose; a cropped arm skews the shoulder-span scale.
- If moves still invert after a clean T-pose, redo step 1. Mirror is the usual culprit, not scale.