23 KiB
Three proposals — Life Underground (Patriot HackFest Fall 2026)
Author: cluster-a. Window: writing on Nov 17, event ends Nov 20 → 3 working days assumed.
All cited libraries verified live this session (PyPI/npm returned HTTP 200): psychrolib, ruptures, cvxpy, scipy, opencv-python, chart.js, @meshtastic/js.
Recon note that shapes everything below: I read the actual repos, not just the brief.
- Stratum is not merely a "phone app" — its core is a deterministic district simulator ("District 7", 6 levels × 4 sectors) whose adapters
p01/p02/p03already model all three of my problems:p01warns from the mains hum (ENF) heard by a phone mic and a CO2 model;p02is a Fair-Share water-filling allocator with per-good life floors scored by "worst-decile served fraction";p03divides a cooling pool with rotating refuge rooms scored by "person-hours above 27.5 °C wet-bulb". It is evidence-heavy (real ENF-WHU grid recordings, GECCO-2018 water data) and genuinely strong. Beating it means out-mechanism-ing it, not re-skinning it. - HollowSignal is a single-sector browser planner (6 neighborhoods, 19k residents) with power/water/heat scenarios, a side-by-side allocation comparison, and refuge routing. It overlaps my problem 2 and (loosely) 3.
- Undercurrent (mesh + hash-chained log + AI triage) barely touches my three.
PROPOSAL 1 — "Blackout Canary"
One-line pitch: A phone-free edge sensor that forecasts minutes-to-cut for power and air as an actual countdown — and keeps warning after the lights go out, because it runs on a hand-crank, not your dying phone.
Problem restatement
The Directorate sheds power and ventilation on its own schedule and lies in the official numbers. Residents get no warning, so a cut arrives as a surprise: no time to fill water, charge lamps, move the frail to a refuge, or open a manual air path. "Warn before the cut" means (a) detect the precursor of an impending shed, (b) convert it into a concrete lead time ("~9 min to power shed", "~22 min to unsafe air"), and (c) deliver that warning on infrastructure that survives the cut itself.
Concrete mechanism (named algorithms, no hand-waving)
Three cheap, independent signals, each with an explicit estimator:
-
Power precursor via light-flicker, not audio. A phototransistor (or a phone camera's rolling shutter) samples a mains-powered lamp at ~1–2 kHz. Two features are extracted:
- Mains frequency (ENF) from flicker: the 100/120 Hz flicker envelope tracks grid frequency; a short-time Goertzel/FFT recovers f(t). This is the same physics Stratum uses, but via light instead of the microphone — robust in a noisy tunnel and workable from a bare photodiode.
- Voltage sag: lamp mean brightness and flicker depth fall as the grid is loaded toward a shed.
- Shed forecast: run CUSUM change-point detection (
ruptures, or a 20-line hand-rolled two-sided CUSUM) on f(t) and brightness to flag the onset of a sustained sag; then fit an EWMA/linear trend to the sag slope and extrapolate the time to cross the shed threshold (Stratum's own numbers: AMBER ≈ 4.79 % loss, shed ≈ 5.24 %). Output = estimated minutes to shed + confidence band. A sudden breaker trip crosses threshold within one sample → emit "imminent, unwarnable" honestly, exactly as Stratum concedes for trips.
-
Air precursor via a first-order CO2 mass-balance. An NDIR/photoacoustic CO2 sensor (Sensirion SCD41, I²C, ~US$25) reads ppm. In a sealed volume the dynamics are
dC/dt = G/V − (Q/V)·(C − C_out), where G = generation (∝ occupancy), V = volume, Q = ventilation airflow. When a ventilation cut drops Q,dC/dtjumps. The node continuously fits (G, Q) from the last few minutes of the CO2 curve by least squares, then integrates the ODE forward to the 1000 / 2000 / 5000 ppm thresholds → minutes-to-unsafe-air. This is textbook indoor-air physics, fully deterministic, and is the piece no competitor turns into a countdown. -
Tamper-evidence against the Directorate. Each node signs its readings (Ed25519). A warning also fires when the crowd-sensed signals diverge from the Directorate's "all-OK" feed — i.e. it catches the Directorate masking a cut, which is the political heart of the scenario.
Resilience is the differentiator's teeth: phones need charging; a power cut kills the very device Stratum relies on. Canary is a hand-crank/solar edge node (ESP32 or RP2040) that keeps sensing, alarms locally (buzzer + LED bar = the countdown), and rebroadcasts over a LoRa mesh so one node's warning reaches a level with no network and no mains.
Architecture + tech stack (all real, checkable, free/open)
- Firmware: ESP32 (Arduino-ESP32 / PlatformIO) or RP2040 (MicroPython). Sensors: phototransistor → ADC; SCD41 → I²C (Sensirion open driver). Mesh: RFM95 LoRa, optionally Meshtastic firmware (open source) with the
@meshtastic/jsclient (verified on npm) for the dashboard link. - Algorithm (authoritative copy, runs the demo): Python —
numpy/scipyfor the ODE least-squares and EWMA,ruptures(verified on PyPI) for CUSUM. Mirrored in C for the firmware. - Dashboard / judge view: Vite + vanilla JS +
chart.js(verified on npm). It replays recorded sensor traces (synthetic + any real ENF trace, e.g. the public ENF-WHU set Stratum already uses) and runs the identical forecast logic (ported to JS or compiled to WASM) so LIVE and REPLAY give the same numbers. - Honesty flag: if no hardware arrives in time, everything except the physical node is still real — ship the firmware source + wiring diagram as "LIVE-ready" and demo the algorithm against replayed traces. Do not fake a device on stage.
3-day build plan
- Day 1: Implement + unit-test the two estimators in Python against synthetic traces with known ground-truth cut times (measure actual lead-time error). Define the trace format. If hardware present, flash ESP32 + read SCD41 + photodiode into a serial log.
- Day 2: Port estimators to JS/WASM; build the replay dashboard with the countdown + confidence band + "imminent/unwarnable" state; add Ed25519 signing and the divergence-vs-official-feed alarm. Wire LoRa broadcast if hardware is up.
- Day 3: Record a clean demo trace where a slow sag is warned ~9 min ahead and an air cut ~20 min ahead; polish judge view; write the "what is real" label table (LIVE/REPLAY/SIM); rehearse the 2.5-min script. Buffer for the inevitable sensor-noise tuning.
Demo script (2.5 min)
- (15 s) "Your phone dies in a blackout. This doesn't." Hold up (or show) the crank node.
- (45 s) Replay a power trace: lamp flicker frequency sags, CUSUM flags the onset, the dashboard counts 9:40 → 0:00; the buzzer/LED fires; the shed lands right at zero. Then replay a trip: the node honestly says "imminent — too fast to warn."
- (45 s) Replay an air trace: CO2 begins climbing, the ODE fit projects "22 min to 2000 ppm," countdown runs, alarm fires with margin to move people.
- (20 s) Flip the Directorate's official feed to "all normal" while the node screams — divergence alarm lights; "it catches them lying."
- (15 s) The label table: what's LIVE, REPLAY, SIMULATED.
Rubric mapping
- Creativity: forecasting minutes-to-cut for air from an ODE and sensing the grid through light on a crank-powered node that outlives the cut — a fresh combination.
- Technical: CUSUM + trend extrapolation + a fitted first-order CO2 ODE + signed mesh, each verifiable against traces with measured lead-time error.
- Impact: a concrete countdown is directly actionable (fill water, move the frail, open manual air) and the resilience angle means it works during the emergency.
- Presentation: the countdown hitting zero exactly as the cut lands is a clean, legible visual beat.
Differentiation
Closest overlap: Stratum p01 (phone-mic ENF hum + CO2 model, AMBER/RED tiers). New angles: (1) a numeric lead-time forecast for both power and air, not just a color tier; (2) the CO2 ODE time-to-threshold, which Stratum does not produce; (3) light-based sensing; (4) the decisive one — phone-independent, crank-powered hardware that survives the cut, directly attacking Stratum's weakness that its sensor is the phone that dies first.
Top 2 feasibility risks + mitigation
- Hardware doesn't arrive / won't behave in 3 days. Mitigation: the Python/JS algorithm and replay dashboard are the graded core and need no hardware; the node is a clearly-labeled stretch. Never fake it on stage.
- Flicker-based ENF is noisy under dim/shared lighting, hurting lead-time accuracy. Mitigation: fuse with brightness-sag and the CO2 channel; report a confidence band; validate lead-time error on replayed real ENF traces and show the number honestly.
Solo vs 2–4 person scoping
- Solo: Python estimators + replay dashboard only, no hardware. Still a complete, demoable, differentiated submission.
- 2 people: add the ESP32 + SCD41 live node and a real crank/solar demo.
- 3–4: add the LoRa mesh relay between two nodes and the signed divergence-vs-official-feed alarm as a full sub-demo.
PROPOSAL 2 — "Equinox" ⚠️ crowded problem, see verdict
One-line pitch: A ration allocator you can't lie your way past: everyone spends an equal budget, market-clearing prices divide power/water/food, and the result is provably envy-free and efficient — with a hard survival floor underneath.
Problem restatement
Split scarce power, water, and food across levels "fairly." The unsolved part every competitor skips: levels will over-report need to grab more, and the Directorate's hand-divides are opaque and unaccountable. A real mechanism must (a) resist strategic lying about demand, (b) be provably fair (no level envies another's bundle), (c) stay efficient (no wasteful split), and (d) guarantee a survival floor regardless.
Concrete mechanism
Competitive Equilibrium from Equal Incomes (CEEI) via the Eisenberg–Gale convex program — the mechanism behind Spliddit and Wharton's course-allocation (Budish's CEEI), applied to rationing:
- Give every resident an equal budget of B virtual tokens (a level's budget = B × its population).
- Goods (kWh, L water, kcal) get market-clearing prices p. Each level buys the bundle maximizing its utility within budget.
- The equilibrium is computed directly by maximizing Nash social welfare:
max Σ_i people_i · log(u_i)s.t.Σ_i x_ig ≤ supply_gfor each good g, withu_ia concave utility over the level's bundle. The maximizer is the CEEI allocation (Eisenberg–Gale duality gives the clearing prices as the constraint multipliers). - Properties that neither competitor provides: Pareto-efficient, envy-free, proportional, and approximately strategyproof in large populations — a single level can't move prices enough to profit by lying, so honest demand is a near-best response. That directly solves the over-reporting problem Stratum's water-filling assumes away.
- Hard survival floor: add
u_i ≥ floor_iconstraints (fair division with guaranteed minimums). Floors are served first; CEEI divides only the surplus above them. - Fairness receipt: each level gets a signed statement of its budget, the clearing prices, its bundle, and an envy-free certificate (no feasible swap is Pareto-improving) — an auditable answer to Directorate opacity.
- Benchmark head-to-head against Stratum's max-min water-filling and the Directorate's deepest-first, on the same scenario, reporting Nash welfare, envy count, worst-decile served fraction, and Jain's index.
Architecture + tech stack
- Solver: Python +
cvxpy(verified on PyPI) with its bundled free solvers ECOS/SCS for the Eisenberg–Gale program;numpy/scipyfor scenario generation and the comparison metrics. The log-utility objective is concave → a clean, reliably solvable convex problem at this scale (tens of levels, 3 goods). - Frontend: Vite + vanilla JS +
chart.js: allocation bars per level, the clearing-price panel, and an envy matrix heatmap (cell (i,j) = how much i would prefer j's bundle; CEEI makes it all ≤ 0). - Optional API: FastAPI if a live "re-solve on slider change" demo is wanted; otherwise precompute scenarios.
3-day build plan
- Day 1: Eisenberg–Gale program in cvxpy with floor constraints; verify envy-freeness and feasibility on 3–4 hand-checkable scenarios; implement the comparison metrics.
- Day 2: Implement Stratum-style max-min and Directorate deepest-first as baselines on identical inputs; wire the frontend (allocation bars, price panel, envy heatmap, metric table).
- Day 3: Build a strategic-lying demo (a level doubles its reported need → show its payoff barely moves under CEEI but balloons under naive proportional split); fairness-receipt export; polish + rehearse.
Demo script (2.5 min)
- (20 s) "Fair isn't just a formula — it has to survive people lying." Show the three goods and the levels.
- (40 s) Run CEEI: allocation bars fill, prices appear, the envy matrix goes all-green (nobody envies anyone); the survival floor line holds under every level.
- (40 s) Side-by-side: Directorate deepest-first (deep levels starve) vs Stratum max-min vs Equinox — metric table shows Equinox with zero envy and competitive worst-decile.
- (30 s) The lying demo: a level inflates demand → under naive split it wins big; under CEEI its gain is ~nil. "You can't game it."
- (10 s) Export a signed fairness receipt.
Rubric mapping
- Creativity: rationing as a strategyproof market with equal incomes — a genuinely different frame from max-min division.
- Technical: a real convex-optimization mechanism (Eisenberg–Gale/Nash welfare) with proven envy-freeness and efficiency, plus the strategyproofness demo.
- Impact: resistance to demand-inflation and an auditable receipt address the real failure modes of hand-divided rationing.
- Presentation: the all-green envy matrix and the "lying doesn't pay" reveal are crisp, legible beats.
Differentiation
Closest overlaps: Stratum p02 (Fair-Share water-filling + life floors + worst-decile metric) and HollowSignal (per-level allocation comparison). New angle: both assume true demand and optimize a division rule; Equinox makes honesty near-optimal (strategyproof-in-the-large CEEI) and ships a mathematical envy-free + Pareto guarantee with an auditable receipt — properties neither competitor claims.
Top 2 feasibility risks + mitigation
- Crowding — this is the most contested of my three problems. Mitigation: only pursue it with the CEEI/strategyproofness angle; a plain allocator here is dominated by Stratum and should not be built.
- Solver edge cases (degenerate prices, zero-demand goods). Mitigation: add tiny Tikhonov regularization and demand floors; cvxpy + SCS handles the regularized problem robustly; validate on hand-checkable cases first.
Solo vs 2–4 person scoping
- Solo: CEEI solver + static scenarios + envy heatmap + the lying demo. Complete.
- 2: add live sliders (FastAPI re-solve) and the full baseline comparison.
- 3–4: add multi-period allocation with carry-over debts (fairness over time, not just one shot) and the signed-receipt audit trail.
VERDICT on problem 2: Recommend against building it unless you commit to the CEEI angle. As a plain fair-divider it is squarely occupied by Stratum (strong, evidence-backed) and HollowSignal. CEEI is the only path to a sharp, defensible contribution here — and even then it competes hardest of my three. If the team wants the surest differentiated win, spend the effort on Proposal 3 instead.
PROPOSAL 3 — "CoolVault" ★ recommended lead pick
One-line pitch: Deep levels stay survivable by banking cold when power is spare and spending it when the wet-bulb climbs — a predictive controller that fights humidity, not just heat, and schedules a thermal battery against a shaky power budget.
Problem restatement
The deepest levels are hottest (geothermal influx + waste heat + poor ventilation) and last in line for the rationed cooling plant. The true danger at ~70 % humidity is wet-bulb temperature, not dry-bulb: above ~27.5 °C wet-bulb the body can't shed heat and people die. Stratum's own notes concede humidity is what makes the deep levels lethal. Simply dividing a cooling pool (what Stratum and HollowSignal do) ignores the two levers that actually help: when you cool and removing moisture. "Keep lower levels livable" means an operational controller, not just an allocation.
Concrete mechanism
A model-predictive controller (MPC) over a physical model:
- Thermal model — lumped-capacitance RC network per level:
C·dT/dt = Q_geo + Q_people + Q_internal − Q_cool, withQ_geothe (roughly constant, depth-scaled) geothermal influx,Q_people ∝ occupancy, andQ_coolthe applied cooling. Standard building-physics first-order model, parameters fit from any temperature log. - Humidity mass-balance + wet-bulb: track moisture from people/infiltration vs dehumidification; compute wet-bulb from (T, RH) with
psychrolib(GetTWetBulbFromRelHum, NREL/ASHRAE-validated — verified on PyPI). This is the real danger metric and the thing the controller actually minimizes. - The "coolth battery": a chilled-water or PCM tank storing cold. State-of-charge is a decision variable — pre-charge it during power-surplus windows (night/off-peak, or whenever Proposal 1/2 say power is cheap) and discharge during peak-heat hours so lethal windows don't depend on live grid power.
- MPC optimization: over a receding N-hour horizon, decision variables are the cooling schedule, the dehumidification schedule, and tank charge/discharge. Objective: minimize person-hours above 27.5 °C wet-bulb + energy cost. Constraints: a time-varying power budget (scarce, from the ration), tank capacity, and plant limits. Solve as an LP/QP with
cvxpyeach step; re-solve as the forecast updates. Fallback if time-boxed: a greedy "pre-charge when spare, discharge above a wet-bulb setpoint, dehumidify first" heuristic still demonstrates the whole idea and is a 1-hour implementation. - The key physical insight that beats pure cooling: at 70 % RH, lowering RH drops wet-bulb more per joule than lowering dry-bulb — so the controller prioritizes dehumidification, which no competitor models at all.
Architecture + tech stack
- Core: Python +
psychrolib(wet-bulb, verified) +cvxpy(MPC LP/QP, verified) orscipy.optimize.linprogfor the fallback +numpyfor the RC integration and scenario generation. All free/open. - Frontend: Vite + vanilla JS +
chart.js(or Plotly) — stacked timelines of dry-bulb, wet-bulb vs the 27.5 °C lethal line, tank state-of-charge, and the power budget, with a live "person-hours saved" counter. - No hardware required — this is a modeling/control deliverable, which is why it's the surest 3-day win.
3-day build plan
- Day 1: RC thermal model + humidity balance + psychrolib wet-bulb, integrated over a day for a deep level under a realistic power budget; validate the uncontrolled baseline crosses the lethal line. Build scenario generator (depth, occupancy, budget profile).
- Day 2: Add the coolth tank and dehumidification as decision variables; implement the greedy heuristic first (guaranteed working), then the cvxpy MPC on top; compute person-hours over threshold for each.
- Day 3: Baselines — Stratum static Fair-Share split and Directorate proportional, same inputs; build the dashboard (wet-bulb timelines, tank SoC, person-hours-saved counter); polish + rehearse. Buffer for MPC tuning; the heuristic is the safety net.
Demo script (2.5 min)
- (20 s) "Down deep it's the humidity that kills — and the cooling arrives when it's already too late." Show the lethal 27.5 °C wet-bulb line.
- (40 s) Uncontrolled / Directorate run: wet-bulb crosses the red line for hours; the person-hours counter climbs alarmingly.
- (50 s) CoolVault run on the same power budget: the tank pre-charges overnight (SoC rises), dehumidification kicks in, and at peak heat the stored cold is spent — wet-bulb stays under the line; counter stays near zero. Point to "dehumidify-first" doing the heavy lifting.
- (20 s) Side-by-side person-hours table: Directorate vs Stratum-split vs CoolVault.
- (10 s) "Same power. Same plant. Scheduling and drying the air is the difference between livable and lethal."
Rubric mapping
- Creativity: treating cooling as a storage + dehumidification scheduling problem and targeting wet-bulb — a frame nobody else uses.
- Technical: a real RC thermal model + psychrometric wet-bulb + an MPC (LP/QP) over a thermal battery, with the greedy fallback proving robustness.
- Impact: measured person-hours-over-lethal-wet-bulb reductions on the same scarce power — directly the thing that keeps deep levels alive.
- Presentation: the wet-bulb line held just under lethal while the tank drains is an unforgettable visual.
Differentiation
Closest overlap: Stratum p03 (divides a static cooling pool with rotating refuge rooms; metric = person-hours > 27.5 °C wet-bulb) and HollowSignal's heat scenario. New angle: Stratum allocates a fixed pool at each instant and measures the metric; CoolVault forecasts wet-bulb and actively controls it — time-shifting cold via storage, removing moisture via dehumidification, and optimizing against a varying budget. It can even sit downstream of Stratum's allocation as the control layer Stratum lacks, which makes it complementary rather than a clone.
Top 2 feasibility risks + mitigation
- MPC tuning eats the clock. Mitigation: the greedy pre-charge/dehumidify-first heuristic is built Day 2 and already demonstrates the thesis; MPC is a strict upgrade, not a dependency.
- Thermal/psychrometric parameters look arbitrary and judges doubt them. Mitigation: source Q_geo, C, and PCM capacity from published ranges, cite them on screen, and run a sensitivity sweep so the conclusion (storage + dehumidification cuts lethal person-hours) holds across parameters, not one lucky set.
Solo vs 2–4 person scoping
- Solo: RC model + wet-bulb + greedy controller + two baselines + dashboard. Complete and strong.
- 2: add the full cvxpy MPC and the sensitivity sweep.
- 3–4: multi-level coupling (shared plant across levels, so cooling becomes a joint schedule) and a direct hand-off from Proposal 2's allocation as the time-varying budget input — the two projects compose into one system.
Cross-cutting recommendation
Build order if the team picks from my three: Proposal 3 (CoolVault) first — clearest open lane, no hardware risk, strong visual. Proposal 1 (Blackout Canary) second — differentiated by the air-ODE countdown and crank-powered resilience, with a solo-safe software-only floor. Proposal 2 (Equinox) only if you commit to the CEEI/strategyproofness angle; otherwise skip — Stratum and HollowSignal already own plain fair-division. Proposals 2 and 3 compose (CEEI budget → CoolVault's power input), as do 1 and 3 (Canary's cheap-power windows → CoolVault's pre-charge trigger), so a 3–4 person team could ship 3 as the spine with 1 feeding it.